EverFocus Flex1.0 Manuale Utente Pagina 36

  • Scaricare
  • Aggiungi ai miei manuali
  • Stampa
  • Pagina
    / 123
  • Indice
  • SEGNALIBRI
  • Valutato. / 5. Basato su recensioni clienti
Vedere la pagina 35
when the APB property of a card is set as enabled and that card is presented
twice consecutively on any enter-door reader or exit-door reader.
The controller generates alarm output(s) according to the settings in the “APB
Fail” column.
Card PIN Fail:
A Card PIN Fail event is generated when a PIN-enabled card is presented at a
reader and an incorrect PIN is entered three times consecutively.
The controller generates alarm output(s) according to the settings in the “Card
PIN error” column.
Door Forced Open:
A Door Forced Open event is generated when the door sensor indicates to the
controller that a door is opened, but no legitimate card has been presented and
a request to exit has not been pressed.
The controller generates alarm output(s) according to the settings in the
“Forced Open” column.
Overtime:
An overtime event occurs when a door is held open for longer than the allowed
time (as set by the system administrator).
The controller generates alarm output(s) according to the settings in the
“Overtime” column.
Reader Lost:
A Reader Lost event will be generated when controller detects that the card
reader appears to have been disconnected from the system.
The controller generates alarm output(s) according to the settings in the
“Reader Lost” column.
Configure an Alarm
All the events can be allocated to any alarm relay output on main module, door module,
and alarm module. The detailed configuration method is introduced in this section.
1. Select the Tab that includes the alarm configuration being changed. For
example, choose “Alarm Setting 1” for “Fire Alarm”. The “Fire Alarm” column
29
Vedere la pagina 35
1 2 ... 31 32 33 34 35 36 37 38 39 40 41 ... 122 123

Commenti su questo manuale

Nessun commento