can set the masking size and position in the private zone setup mode.
In this mode, you can press
Shift” + “6” to increase masking horizontal size;
Shift” + “4” to decrease masking horizontal size;
Shift” + “2” to increase masking vertical size;
Shift” + “8” to decrease masking vertical size;
Shift Joystick to select the position where the masking is located.
Enter” to confirm the size and position, and then the masking will turn into green again.
18. AUTO REGRESSAuto regress to the shortest path during set a position. It can
shorten the response delay, and increase the response performance and speed dome
lifetime.
ON: Enable the auto regress function.
OFF: Disable the auto regress function.
19. X CNT X-axis counter. This counter counts the x axis movement, and 1 is counted
when the speed dome pans 360°.
20. Y CNT Y-axis counter. This counter counts the y axis movement, and 1 is counted
when the speed dome tilts 180°.
21. PO CNT Position counter. This counter counts the go-position times, 1 is counted
when speed dome goes to a position once.
22. OP HR Operation hour. This counter counts the operation hours.